Civil MDC

June 23, 2023

Design of Isolating Intermediate footing 1

Design of Isolating Intermediate footing

Designing an isolating intermediate footing involves creating a foundation that provides support and isolates the loads of an individual column or set of columns from the adjacent footings or structures. This type of footing is commonly used when there is a need to prevent the transfer of loads or to address differential settlements between columns. […]

Design of Isolating Intermediate footing Read More »

Design of Isolating footing at edg. 2

Design of Isolating footing at edg.

Designing an isolating footing at the edge involves creating a foundation that isolates the supported structure from the adjacent structure or ground. This type of footing is commonly used when there is a need to prevent differential settlements or to minimize the transfer of loads between structures. Here are the key steps involved in designing

Design of Isolating footing at edg. Read More »

Design of Column for internal frame 3

Design of Column for internal frame

Designing a column for an internal frame involves considering various factors, including the load requirements, structural stability, material selection, and architectural considerations. Here are some key steps to consider when designing a column for an internal frame: Load Analysis: Determine the types and magnitudes of the loads that the column will be subjected to. Consider

Design of Column for internal frame Read More »

Design of Column for external frame 4

Design of Column for external frame

Designing a column for an external frame involves considering several factors, including the load requirements, structural stability, material selection, and architectural considerations. Here are some key steps to consider when designing a column for an external frame: Load Analysis: Determine the types and magnitudes of the loads that the column will be subjected to. Consider

Design of Column for external frame Read More »

DESGIN A COLUMN SUBJECTED TO TENSION FORCE 5

DESGIN A COLUMN SUBJECTED TO TENSION FORCE

Objective: Design a column to resist a specific tension force of magnitude F. Material Selection: Choose a material with high tensile strength, such as steel or prestressed concrete, to effectively withstand the tension force.Cross-Sectional Shape and Dimensions: Select a suitable cross-sectional shape for the column, such as rectangular, square, or circular, based on structural efficiency

DESGIN A COLUMN SUBJECTED TO TENSION FORCE Read More »

Design Of Columns For The Last Three Floors 6

Design Of Columns For The Last Three Floors

Designing columns for the last three floors of a building involves considering several factors, including the load requirements, structural stability, material selection, and construction considerations. Here are some key steps to consider when designing columns for the uppermost floors: Load analysis: Determine the types and magnitudes of the loads that the columns will be subjected

Design Of Columns For The Last Three Floors Read More »

DESIGN OF SECTION 7

DESIGN OF SECTION

Designing a section involves determining the appropriate dimensions and shape for a structural or architectural element. The specific design considerations will vary depending on the type of section being designed, such as a beam, column, wall, or slab. Here are some general steps to consider when designing a section: Determine the functional requirements: Understand the

DESIGN OF SECTION Read More »

DESIGN OF CORBLES 9

DESIGN OF CORBLES

Corbels are structural elements that project from a wall or column to support a load. They are commonly used in architecture and construction to provide additional support and decorative features. The design of corbels involves several considerations, including structural integrity, material selection, aesthetics, and installation method. Here are some key factors to consider when designing

DESIGN OF CORBLES Read More »

Scroll to Top