COLUMN CHART FOR SYMMETRICALLY REINFORCED RECTANGULAR COLUMNS BENT ABOUT THE X-X AXIS TO EN 1992-1 : 2004 1

COLUMN CHART FOR SYMMETRICALLY REINFORCED RECTANGULAR COLUMNS BENT ABOUT THE X-X AXIS TO EN 1992-1 : 2004

A column chart is a data visualization where each category is represented by a rectangle, with the height of the rectangle being proportional to the values being plotted. Column charts are also known as vertical bar charts Column charts are useful for showing data changes over a period of time or for illustrating comparisons among items. In […]

COLUMN CHART FOR SYMMETRICALLY REINFORCED RECTANGULAR COLUMNS BENT ABOUT THE X-X AXIS TO EN 1992-1 : 2004 Read More »

POST-TENSIONED ANALYSIS & DESIGN to BS EN 1992-1:2004 4

POST-TENSIONED ANALYSIS & DESIGN to BS EN 1992-1:2004

Post-tensioned concrete means that the concrete is poured and then the tension is applied-but it is still stressed before the loads are applied so it is still prestressed. … The program provides for the ultimate strength and service stress design and analysis of one-way beam and slab and two-way flat plate systems.

POST-TENSIONED ANALYSIS & DESIGN to BS EN 1992-1:2004 Read More »

RIGOROUS ONE-WAY SOLID RC SLAB DESIGN to EN 1992-1 : 2004 8

RIGOROUS ONE-WAY SOLID RC SLAB DESIGN to EN 1992-1 : 2004

The one-way slab is a slab, which is supported by parallel walls or beams, and whose length to breadth ratio is equal to or greater than two and it bends in only one direction (spanning direction) while it is transferring the loads to the two supporting walls or beams, because of its geometry.

RIGOROUS ONE-WAY SOLID RC SLAB DESIGN to EN 1992-1 : 2004 Read More »

RESISTANCE of AXIALY LOADED WALLS/SLABS to BSEN 1992-1 & 3 11

RESISTANCE of AXIALY LOADED WALLS/SLABS to BSEN 1992-1 & 3

The axial resistivity, Ri, is a measure of the Ohmic resistance of the intracellular medium of a neuronal process (e.g., axon or dendrite). Ri is defined as the resistance of the medium contained within a fixed-radius cylinder of unit length and unit cross-sectional area, measured between the flat ends of the cylinder.

RESISTANCE of AXIALY LOADED WALLS/SLABS to BSEN 1992-1 & 3 Read More »

BENDING AND AXIAL FORCE to EN 1992-1 : 2003 14

BENDING AND AXIAL FORCE to EN 1992-1 : 2003

Axial tension force can be defined as the force acting on a body in its axial direction. It’s a pulling force that will cause the body to elongate linearly in the positive direction causing a change in its dimension. Axial–Flexual Response of Cross-Sections The actual bending in a flexural member is about a single axis, defined earlier

BENDING AND AXIAL FORCE to EN 1992-1 : 2003 Read More »

CONTINUOUS CONCRETE BEAM DESIGN to BS 8110:2005 Table 3.5 15

CONTINUOUS CONCRETE BEAM DESIGN to BS 8110:2005 Table 3.5

CONTINUOUS CONCRETE BEAM are structural elements that support loads applied transversely to the beam axis, which produce a combination of shear and bending stresses. Concrete beams are usually continuous, this is, they span between multiple supports acting structurally as a single element.

CONTINUOUS CONCRETE BEAM DESIGN to BS 8110:2005 Table 3.5 Read More »

2-WAY SPANNING INSITU CONCRETE SLABS to BS 8110:2005 (Table 3.14) 16

2-WAY SPANNING INSITU CONCRETE SLABS to BS 8110:2005 (Table 3.14)

To design a two-way spanning in-situ concrete slab using Table 3.14 of BS 8110:2005, you will need the following information: Loadings: Determine the imposed load, dead load, and any other relevant loadings acting on the slab. These loads will depend on the specific project and its requirements. Span dimensions: Determine the span dimensions of the

2-WAY SPANNING INSITU CONCRETE SLABS to BS 8110:2005 (Table 3.14) Read More »

RIBBED SLAB DESIGN to BS 8110:2005 using table 3.12 coefficients 18

RIBBED SLAB DESIGN to BS 8110:2005 using table 3.12 coefficients

A Ribbed Slab gives considerable extra strength in one direction while a waffle slab gives added strength in both directions. And this is possible only in monolithically cast concrete which is the two-way grid of beams. In comparison to the solid slab, the span limits of ribbed slabs are considerably longer.

RIBBED SLAB DESIGN to BS 8110:2005 using table 3.12 coefficients Read More »